Menu
Peptide Database
Results
No peptides found
Featured

Use search to browse all 100+ peptides

GHRP-6

Growth Hormone Releasing Peptide-6, Growth hormone-releasing hexapeptide, His-D-Trp-Ala-Trp-D-Phe-Lys-NH2

Quick Stats
Studies 702
Trials 0
2021 pubmed 3 citations

A quantitative UHPLC-MS/MS method for the growth hormone-releasing peptide-6 determination in complex biological matrices and transdermal formulations.

Esposito. Cloé L CL; Ac. Araceli Garcia AG; Laszlo. Elise E; Duy. Sung Vo SV; Michaud. Catherine C; Sauvé. Sébastien S; Ong. Huy H; Marleau. Sylvie S; Banquy. Xavier X; Brambilla. Davide D

Key Findings

  • Error

Practical Outcomes

  • Error

Summary

Error: Timeout.

Abstract

Growth hormone-releasing peptide-6 (GHRP-6) is part of a group of small synthetic peptides with potent GH-releasing activity that have gained attention in the last two decades by virtue of their cyto- and cardioprotective effects. Despite numerous preclinical studies highlighting the potential cardiovascular benefits of GHRP-6, confirmation of clinical efficacy is still awaited. Recent advances in transdermal drug delivery systems have been made to address challenges related to the poor skin permeation rate of peptides by using pain-free microneedle (MN) devices. Accordingly, highly sensitive and validated analytical methods are required for the potential clinical translation of MN-based peptides. The ultra-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) methods developed in this study aimed to quantify GHRP-6 in biological matrices (plasma, skin) and dissolving polymeric MNs. UHPLC/MS-MS method detection limits of 0.1, 1.1, 0.9 and 1.5&#xa0;ng/mL were achieved in neat solution, plasma, MN polymer solution, and skin matrices, respectively. Method validation also involved assessment of precision, accuracy, limits of quantification, linearity of matched calibration curves (R<sup>2</sup>&#xa0;&gt;&#xa0;0.990), extraction recovery, matrix effect, stability studies, selectivity, and carry-over effect. Additionally, quality control samples were analyzed at three concentration levels to determine recovery (85-109%) and accuracy/bias (3.2-14.7%). Intra- and inter-day precision were within the range of acceptance (RSDs of 3.0-13.9% and 0.4-14.5%, respectively). The validity and applicability of such methods were successfully demonstrated for transdermal GHRP-6 delivery using GHRP-6-loaded MN patches applied to pig skin.

Study Information

Provider

pubmed

Year

2021

Date

2021-05-26T00:00:00.000Z

DOI

10.1016/j.talanta.2021.122555

Citations

3